Thermal Magnetic Residual MCCB TDK5L
Scope of Application
TDK5L series molded case current circuit breaker with residual current protection (hereinafter referred to as circuit breaker)is suitable for distribution network with a frequency of AC 50Hz,the rated working voltage of 400V,the rated insulation voltage of 1000V and the rated current of 800A.It can be used to provide indirect contact protection for people,prevent fire danger caused by grounding fault current caused by equipment insulation damage,distribute electric energy,protect overload and short circuit of lines and equipment,and also be used for infrequent switching of lines and infrequent starting of motors.
The rated residual current I△n and the maximum operating time of the rated residual current can be adjusted on site according to the actual situation;When the phase voltage is reduced to 85V,the leakage protection module can still work normally and has the function of leakage alarm output.
The products conform to IEC60947-2 standards.
Model and Meaning

| Serial No. | Item meaning |
| ① | Enterprise code:TALEMOD |
| ② | MCCB(Molded Case Circuit Breaker) |
| ③ | Design No. |
| ④ | With residual current protection |
| ⑤ | Frame grade current(A):Inm=125,Inm=160,Inm=250,Inm=400,Inm=630i, Inm=630,Inm=800 |
| ⑥ | i:Capacity expanion current;Conventioal no code |
| ⑦ | Breaking capaciy.C:Low breaking;S:Ordinary breaking;L:Midle breaking;M:High breaking |
| ⑧ | Surface cover type:S:Single-cap;Double-cap no code |
| ⑨ | Operating mode:Manual direct operation:no code;Z:Operate by rotating handle; P:Electric operation |
| ⑩ | No.of poles:3:three-pole;4:four-pole |
| ⑪ | Release mode and accessory code |
| ⑫ | 4-pole product code;3-pole product no code |
Note: 4-pole product code
Type A: Overcurrent tripping element is not installed at N pole, and N pole is always ON andnot combined with other three poles.
Type B: Overcurrent tripping element is not installed at N pole, and N pole is combined with otherthree poles (N pole is combined first and then separated).
Classification of Circuit Breakers
Classified according to the number of poles: 3-pole and 4-pole;
Classified according to the application: For power distribution and motor protection;
Classified according to the operation modes: Operated by handle, electric operation (denoted byP), operated by rotating handle (denoted by Z for switchgear).
Main Technical Parameters
| Model | TDK5L-125 TDK5L-160 | TDK5L-250 | TDK5L-400 TDK5L-630i | TDK5L-630 TDK5L-800 | |||||||||||||
| Frame grade curent Inm(A) | 125,160 | 250 | 400,630i | 800 | |||||||||||||
| Rated current In(A) | 16,20,25,32, 40,50,63,80, 100,125,140,160 |
100,125,140, 160,180,200, 225250 |
225,250,315, 350,400,500, 630 |
400,500,630, 700800 |
|||||||||||||
| No.of poles | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | |||||||||
| Rated insulation voltage Ui(V) | 1000 | 800 | |||||||||||||||
| Rated operating voltage Ue(V) | AC400 | ||||||||||||||||
| Ratedimpulse withstand voltage Uimp(kV) | 8 | ||||||||||||||||
| Flashover distance(mm) | 50 | 100 | |||||||||||||||
| Breaking capacity level | C | S | L | M | C | S | L | M | C | S | L | M | C | S | L | M | |
| Ultimate short-circuit breaking capacity Icu(kA) | 25 | 30 | 36 | 50 | 25 | 30 | 36 | 50 | 42 | 50 | 50 | 70 | 42 | 50 | 50 | 70 | |
| Operating short-circuit breaking capacity Ics(kA) | 15 | 15 | 25 | 36 | 15 | 15 | 25 | 36 | 25 | 25 | 50 | 70 | 25 | 36 | 50 | 70 | |
| Rated residual operating curent I△n(mA) | 100/300/500 | 300/500/1000 | |||||||||||||||
| Rated residual non-operating current I△no(mA) | 1/2I△n | ||||||||||||||||
| Residual current protection operation time | I△n | 2I△n | 5I△n | 10I△n | I△n | 2I△n | 5I△n | 0I△n | I△n | 2I△n | 5I△n | 10I△n | I△n | 2I△n | 5I△n | 10I△n | |
| Maximum breaking time (s) | Non-delay type | 0.3 | 0.15 | 0.04 | 0.04 | 0.3 | 0.15 | 0.04 | 0.04 | 0.3 | 0.15 | 0.04 | 0.04 | 0.3 | 0.15 | 0.04 | 0.04 |
| Delay time | 0.4/1 | ||||||||||||||||
| Operational performance (times) | Powered | 1500 | 1000 | 1000 | 1000 | ||||||||||||
| Not powered | 8500 | 7000 | 4000 | 4000 | |||||||||||||
| Total | 10000 | 8000 | 5000 | 5000 | |||||||||||||
Structure and Working Principler
Structure
The series of circuit breakers are electronic current-operated leakage protectors. The main components include main switch (including over.curent release), zero-sequence curent transformer,electronic amplification components,leakage release, test device, all of which are installedin a plastic housing.
Working principle
In case of any leakage or electric shock in the protected circuit, the zero sequence current transformer has a signal output. When the signaloutput reaches a certain value, it tnggers the thynistor to conduct and makes the leakage release act, thus drving the traction bar to disconnecithe operating mechanism in a short time and cut off the power supply, thus realizing the leakage protection function. (The schematic diagramof working principle is as follows)