Thermal Magnetic MCCB TDK5
Scope of Application
TDK5 series molded case circuit breaker(hereinafter referred to as circuit breake)with rated insulation voltage of 1000V is suitable for infrequent switching and infrequent starting of motor in circuits with frequency of AC 50Hz,rated workng voltage of 415V and rated working current of 800A. The circuit breaker has the functions of overload,short circuit and undervoltage protection,which can protect the circuit and power supply equipment from damage.
Circuit breaker can be installed vertically (i.e.vertically)or horizontally (i.e.transversely).
Circuit breaker has isolation function,and their corresponding symbols are: .
Circuit breaker products shall comply with the following standards:
IEC60947-1 General
IEC60947-2 Low Voltage Circuit Breaker
IEC60947-4-1 Electromechanical Contactors and Motor Starters
IEC60947-5-1 Electromechanical Control Circuit Electrical Appliance
Model and Meaning

| Serial No. | Item meaning |
| ① | Enterprise code:TALEMOD |
| ② | MCCB(Molded Case Circuit Breaker) |
| ③ | Design No. |
| ④ | Frame grade current(A):Inm=63,Inm=100,Inm=125i,Inm=125,Inm=160,Inm=250, Inm=400,Inm=630i,Inm=800 |
| ⑤ | i:Capacity expanion current;Conventional no code |
| ⑥ | Breaking capacity:C:Low breaking;S:Ordinary breaking;L:Middle breaking;M:High breaking |
| ⑦ | Surface cover type:S:Single-cap;Double-cap no code |
| ⑧ | Operating mode:Manual direct operation:no code;Z:Operate by rotating handle; P:Electric operation |
| ⑨ | No.of poles:3:three-pole;4:four-pole |
| ⑩ | Release mode and accessory code |
| ⑪ | 4-pole product code;3-pole product no code |
Note: 4-pole product code
Type A: Overcurrent tripping element is not installed at N pole, and N pole is always ON andnot combined with other three poles.
Type B: Overcurrent tripping element is not installed at N pole, and N pole is combined with otherthree poles (N pole is combined first and then separated).
Main Technical Parameters
| Model | TDK5-63 TDK5-100 TDK5-125i |
TDK5-125 TDK5-160 |
TDK5-250 | TDK5-400 TDK5-630i | TDK5-800 | ||||||||||||||||
| Frame grade curent Inm(A) | 63,100,125i | 125,160 | 250 | 400,630i | 800 | ||||||||||||||||
| Rated current In(A) | 10,16,20,25, 32,40,50,63, 80,100,125 |
16,20,25,32, 40,50,63,80, 100,125, 140,160 |
100,125,140, 160,180,200, 225,250 |
225,250,315, 350,400,500, 630 |
630,700, 800 |
||||||||||||||||
| No.of poles | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | |||||||||||
| Rated insulation voltage Ui(V) | 800 | 1000 | |||||||||||||||||||
| Rated operating voltage Ue(V) | AC400,AC415 | ||||||||||||||||||||
| Rated impulse withstand voltage Uimp(kV) | 8 | 12 | |||||||||||||||||||
| Flashover distance(mm) | 50 | 100 | |||||||||||||||||||
| Breaking capacity level | C | S | L | M | C | S | L | M | C | S | L | M | C | S | L | M | C | S | L | M | |
| Ultimate short-circuit breaking capacity Icu(kA) | 15 | 25 | 35 | 50 | 25 | 35 | 36 | 50 | 25 | 35 | 36 | 50 | 42 | 50 | 50 | 70 | 42 | 50 | 50 | 70 | |
| Operating short-circuit breaking capacity Ics(kA) | 10 | 18 | 21 | 30 | 15 | 7.5 | 25 | 36 | 15 | 18 | 25 | 36 | 25 | 25 | 50 | 70 | 25 | 36 | 50 | 70 | |
| Operational performance (times) | Powered | 1500 | 1500 | 1000 | 1000 | 500 | |||||||||||||||
| Not powered | 8500 | 8500 | 7000 | 4000 | 2500 | ||||||||||||||||
| Total | 10000 | 10000 | 8000 | 5000 | 3000 | ||||||||||||||||
Protection Characteristics
Power distribution
| Rated current (A) | Thermal release (ambient temperature+40℃) | Operating current of electromagnetic release(A) | |
| 1.05In (cold)non-operating time (h) | 1.3In(hot)operating time(h) | ||
| 16≤In≤63 | Non-operating within 1 hour | ≤1 | 10A-40A:400A±20% 50A-800A:10In±20% |
| 63<In≤800 | Non-operating within 2 hours | ≤2 | |
For protecting motors
| Rated current (A) | Thermal release (ambient temperature+40℃) | Operating current of electromagnetic release(A) |
||||
| 1.0In (cold) non-operating time(h) |
1.2In(hot) operating time(h) |
1.5In(hot) operating time(h) |
7.2In(cold) operating time(h) |
Trippinglevel | 10A-40A: 400A±20% 50A-800A: 12In±20% | |
| 10≤In≤25 | Non-operating within 2 hours | ≤2 | ≤2min | 0.5s<Tp≤5s | 5 | |
| 25<In≤250 | ≤4min | 4s<Tp≤10s | 10 | |||
| 250<In≤800 | ≤8min | 6s<Tp≤20s | 20 | |||
Classification of Circuit Breakers
Classified according to the number of poles: 3-pole and 4-pole;
Classified according to the application: For power distribution and motor protection;
Classiied according to the operation modes, Operated by handle, electric operation (denoted by p), operated by rotating handle idenoted
by Z for switchgear).
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box