Leave Your Message

Thermal Magnetic MCCB TDK2

TDK2 series molded case circuit breaker with rated insulation voltage of 1000V is suitable for infrequent switching and infrequent starting of motor in circuits with frequency of 50Hz AC, rated working voltage of 690V and below, and rated working current of 800A (TDK2-800 without protection motor). The circuit breaker has the functions of overload short circuit and undervoltage protection, which can protect the circuit and power supply equipment from damage. Three adjustable delay functions are added to the product, which are 0.8xIn, 0.9xIn, 1.0xIn respectively.

    Model and Meaning

    未标题-5.jpg

    Serial No.     Item meaning
    Enterprise code:TALEMOD
    MCCB(Molded Case Circuit Breaker)
    Design No.
    Frame grade current(A)optional code:Inm=63,Inm=125,Inm=250,Inm=400,Inm=630,Inm=800
    UItimate short circuit breaking capacity:L:Standard (25,35,50kA);M:High breaking(50,65kA)
    Operation mode:  Manual direct operation: no code; Z: Operate by rotating handle;P: Electric operation
    No.of poles:,3:three-pole,4:four-pole
    Release mode and accessory code
    Code:For distribution: no code; 2: For motor protection
    Rated current(See Technical Parameters in Table)
    4-pole product code; 3-pole product no code
    Installation modes are optional:Front wiring of board;Rear wiring of board;Plug-in wiring Special mode(negotiated by user and factory)
    Other accessories are optional:Mechanical interlocking between two circuit breakers

    Note: 4-pole product code

    Type A: Overcurrent tripping element is not installed at N pole, and N pole is always ON and notcombined with other three poles.

    Type B: Overcurrent tripping element is not installed at N pole, and N pole is combined with otherthree poles (N pole is combined first and then separated).

    Type C: Overcurrent tripping element is installed at N pole, and N pole is combined with other threepoles (N pole is combined first and then separated).

    Type D: Overcurrent tripping element is installed at N pole, and N pole is always ON and not combinedwith other three poles.

    Main Technical Parameters

    Model TDK2-63 TDK2-125 TDK2-250 TDK2-400 TDK2-630 TDK2-800
    Frame grade current Inm(A) 63 125 250 400 630 800
    Rated current In(A) 10,16,20,25,
    32,40,50,63
    16,20,25,32,
    40,50,63,80,
    100,125
    100,125,140,
    160,180,200,
    225,250
    225,250,315,
    350,400
    400,500,
    630
    630,700,
    800
    No.of poles 3 4 3 4 3 4 3 4 3 4 3 4
    Rated insulation voltage Ui(V) 800 1000
    Rated operating voltage Ue(V) AC400 AC400,AC690
    Rated impulse withstand voltage Uimp(kV) 8 12
    Flashover distance(mm) 50 100
    Breaking capacity level L M H L M H M H M H M H
    Ultimate short-circuit breaking capacity
    Icu(kA)
    AC690V
    AC400V 25 50 70 100 50 70 100 70 100 70 100 75 100
    Operating short-circuit breaking capacity
    Ics(kA)
    AC690V
    AC400V 18 35 50 70 35 50 70 70 75 70 75 75 75
    Operational performance (times) Powered 1500 1500 1000 1000 1000 500
    Not powered 8500 8500 7000 4000 4000 2500
    Total 10000 10000 8000 5000 5000 3000

    Scope of Application

    TDK2 series molded case circuit breaker (hereinafter referred to as circuit breaker) with ratedinsulation voltage of 1000V is suitable for infrequent switching and

    infrequent starting of motor incircuits with frequency of 50Hz AC, rated working voltage of 690V and below, and rated workingcurrent of 800A(TDK2-800 without

    protection motor).

    The circuit breaker has the functions of overloadshort circuit and undervoltage protection, which can protect the circuit and power supply equipmentfrom damage.

    Three adjustable delay functions are added to the product, which are 0.8xIn, 0.9xIn,1.0xIn respectively.

    Circuit breaker can be installed vertically (i.e. vertically) or horizontally (i.e. transversely).Circuit breaker has isolation function, and its corresponding symbol is:

    Circuit breaker products comply with the following standards:

    IEC60947-1 General

    IEC60947-2 Low Voltage Circuit Breaker

    IEC60947-4-1 Electromechanical Contactors and Motor Starters

    IEC60947-5-1 Electromechanical Control Circuit Electrical Appliance

    Protection Characteristics

    For power distribution

    Rated current (A) Thermal release (ambient temperature+40℃) Operating current of electromagnetic release(A)
    1.05In(cold)non-operating time (h) 1.3In(hot)operating time(h)
    10≤In≤63 Non-operating within 1 hour ≤1 10In±20%
    63<In≤100 Non-operating within 2 hours ≤2
    100<In≤800 Non-operating within 2 hours ≤2 5In±20%,10In±20%

    For protecting motors

    Circuit breaker model Thermal release (ambient temperature+40℃) Operating current of electromagnetic release(A)
    1.0In  (cold)
    non-operating
    time(h)
    1.2In(hot)
    operating
    time(h)
    1.5In(hot)
    operating
    time(h)
    7.2In(cold)
    operating
    time(h)
    Tripping level
    TDK2-63L,M,H Non-operating within 2 hours ≤2 ≤2min 0.5s<Tp≤5s 5 12In±20%
    TDK2-125L,M,H ≤4min 4s<Tp≤10s 10
    TDK2-250L,M,H TDK2-400M,H
    TDK2-630M,H
    TDK2-800M,H
    ≤8min 6s<Tp≤20s 20

    Note: The operating current value of 10 ~ 25A electromagnetic trip of TDK2-63 L, M is 300A±20%