Modular DIN Rail Products
- Miniature Circuit Breaker (MCB)
- 18mm Width DPN MCB
- Isolator Switch
- Residual Current Circuit Breaker (RCCB)
- Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Fuse
- Arc Fault Detection Device (AFDD)
- Surge Protection Device (SPD)
- Reclosing Device
- MCB Accessories
- Safety Breaker
- Earth Leakage Safety Breaker
- Safety Breaker with Outer Cover
- Earth Leakage Satety Breaker with Outer Cover
- Plug in Type Miniature Circuit Breaker (MCB)
- Plug in Type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Modular Contactor
- Relay
- Transfer Switch
- Smart Molded Case Circuit Breakers
- PV Systems
- Distribution Box
Smart Residual MCCB(Reclosing Type) TDK3EL
Model and Meaning

| Serial No. | Item meaning |
| ① | Enterprise code:TALEMOD |
| ② | MCCB(Molded Case Circuit Breaker) |
| ③ | Design No. |
| ④ | Electronic &adjustable |
| ⑤ | With residual current protection |
| ⑥ | Frame grade current (A)Inm=125,Inm=250,Inm=400,Inm=630,Inm=800 |
| ⑦ | Automatic reclosing of leakage trip |
| ⑧ | Y:LCD;S:Digital |
Main Technical Parameters
| Model | TDK3EL-125CY TDK3EL-125CS |
TDK3EL-250CY TDK3EL-250CS |
TDK3EL-400CY TDK3EL-400CS |
TDK3EL-630CY TDK3EL-630CS |
TDK3EL-800CY TDK3EL-800CS |
|
| Frame grade curent Inm(A) | 125 | 250 | 400 | 630 | 800 | |
| No.of poles | 3P+N | 3P+N | 3P+N | 3P+N | 3P+N | |
| Rated operating voltage Ue(V) | AC400/50Hz | |||||
| Rated insulation voltage Ui(V) | 1000 | |||||
| Rated impulse withstand voltage Uimp(kV) | 8 | |||||
| Flashover distance(mm) | ≯50 | ≯100 | ||||
| Ultimate short-circuit breaking capacity Icu(kA) | 5070(H) | 6585(H) | ||||
| Operating short-circuit breaking capacity Ics(kA) | 3550(H) | 4265(H) | ||||
| Rated residual short-circuit making (breaking) capacity I△m(kA) | 12.5 17.5(H) | 16.25 21.5(H) | 16.25 | |||
| Rated short-time withstand current Icw(kA)/s | 1.5 | 3 | 5 | 8 | 10 | |
| Residual current operating characteristics | AC type | |||||
| Rated residual operating curent I△n(mA) | 50/100/200/300/400/500/600/800 MCU automatic tracking or manual setting |
100/200/300/400/500/600/800/ 1000 MCU automatic tracking or manual setting |
||||
| Residual operating time characteristics | Delayed/non-delayed type | |||||
| Limit non-drive time of delayed type(s) | 0.06/0.1/0.2 Optional:2I△n | |||||
| Breaking time (s) | I△n≤0.5;2I△n≤0.2;5I△n≤0.15 | |||||
| Auto reclosing time (s) | 20~60 | |||||
| Operational performance (times) | Powered | 1500 | 1000 | 1000 | 500 | |
| Not powered | 8500 | 7000 | 4000 | 2500 | ||
| Total | 10000 | 8000 | 5000 | 3000 | ||
| Overload and short circuit characteristics | Three-stage protection,electronically adjustable,see "Description of Protection Characteristics"for details | |||||
| Overvoltage protection value (V) | Set value (250~300)±5% | |||||
| Undervoltage protection value (V) | Set value(145~200)±5% | |||||
| Link control delay time(ms) | ≤40ms | |||||
| Communication delay time(ms) | ≤200ms | |||||
Main Functions and Features
Core processing and interaction design
The device uses a high-performance 32-bit ARM microprocessor, which can complete signal processing and intelligent control in real time, providing core computing power support for the stable operation of the equipment. It is also equipped with an LCD display in Chinese and English, creating a friendly human-machine interface (HMI), which greatly simplifies the operation process and takes into account the technical performance and ease of use of the equipment.
Residual current protection and dynamic regulation
In terms of residual current (leakage) protection, the device supports online setting of residual current levels and has a reclosing function, which can flexibly adapt to the protection needs of different scenarios; in addition, the device can monitor and track the residual current of the line in real time, and automatically adjust the protection level according to actual conditions. While providing precise protection, it effectively guarantees the operation rate and reliability of the product.
Multiple protection functions and parameter management
The device has a complete protection system, including long-delay, short-delay, and instantaneous three-stage protection (using an electronic tripping method that is independent of the power supply voltage), as well as overvoltage, undervoltage, and phase loss protection. It also has a high breaking capacity to ensure the reliability of line short-circuit protection. At the same time, it supports online setting and modification of protection functions and parameters, and can also identify and display trip types such as residual current, lock, overload, undervoltage, overvoltage, and phase loss, and store, query, and delete related records to facilitate user management and fault tracing.
Expanded functionality and communication capabilities
The network model of the device has communication functions, which can realize remote communication, telemetry, remote control and remote adjustment to meet the needs of intelligent remote management. In addition, it also provides optional plug-in lightning protection modules and infrared communication functions. Users can flexibly expand the device's protection capabilities and data transmission methods according to actual usage scenarios, thereby improving the device's adaptability and practicality.
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box