Modular DIN Rail Products
- Miniature Circuit Breaker (MCB)
- 18mm Width DPN MCB
- Isolator Switch
- Residual Current Circuit Breaker (RCCB)
- Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Fuse
- Arc Fault Detection Device (AFDD)
- Surge Protection Device (SPD)
- Reclosing Device
- MCB Accessories
- Safety Breaker
- Earth Leakage Safety Breaker
- Safety Breaker with Outer Cover
- Earth Leakage Satety Breaker with Outer Cover
- Plug in Type Miniature Circuit Breaker (MCB)
- Plug in Type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Modular Contactor
- Relay
- Transfer Switch
- Smart Molded Case Circuit Breakers
- PV Systems
- Distribution Box
Smart Residual MCCB(Photovoltaic Type) TDK3ELG
Model and Meaning

| Serial No. | Item meaning |
| ① | Enterpise code:TALEMOD |
| ② | MCCB(Molded Case Circuit Breaker) |
| ③ | Design No. |
| ④ | Electronic |
| ⑤ | With residual current protection |
| ⑥ | G:Photovoltaic type |
| ⑦ | Frame grade current(A):Inm=125,Inm=250,Inm=400,Inm=630,Inm=800 |
| ⑧ | Automatic reclosing |
| ⑨ | Y:LCD;B:Bluetooth |
| ⑩ | Accessory code |
| ⑪ | ZB:Carrier module |
| ⑫ | W:Temperature detection |
Main Technical Parameters
| Model | TDK3EL-125CY TDK3EL-125CS |
TDK3EL-250CY TDK3EL-250CS |
TDK3EL-400CY TDK3EL-400CS |
TDK3EL-630CY TDK3EL-630CS |
TDK3EL-800CY TDK3EL-800CS |
|
| Frame grade curent Inm(A) | 125 | 250 | 400 | 630 | 800 | |
| No.of poles | 3P+N | 3P+N | 3P+N | 3P+N | 3P+N | |
| Rated operating voltage Ue(V) | AC400/50Hz | |||||
| Rated insulation voltage Ui(V) | 1000 | |||||
| Rated impulse withstand voltage Uimp(kV) | 8 | |||||
| Flashover distance(mm) | ≯50 | ≯100 | ||||
| Ultimate short-circuit breaking capacity Icu(kA) | 5070(H) | 6585(H) | ||||
| Operating short-circuit breaking capacity Ics(kA) | 3550(H) | 4265(H) | ||||
| Rated residual short-circuit making (breaking) capacity I△m(kA) | 12.5 17.5(H) | 16.25 21.5(H) | 16.25 | |||
| Rated short-time withstand current Icw(kA)/s | 1.5 | 3 | 5 | 8 | 10 | |
| Residual current operating characteristics | AC type | |||||
| Rated residual operating curent I△n(mA) | 50/100/200/300/400/500/600/800 MCU automatic tracking or manual setting |
100/200/300/400/500/600/800/ 1000 MCU automatic tracking or manual setting |
||||
| Residual operating time characteristics | Delayed/non-delayed type | |||||
| Limit non-drive time of delayed type(s) | 0.06/0.1/0.2 Optional:2I△n | |||||
| Breaking time (s) | I△n≤0.5;2I△n≤0.2;5I△n≤0.15 | |||||
| Auto reclosing time (s) | 20~60 | |||||
| Operational performance (times) | Powered | 1500 | 1000 | 1000 | 500 | |
| Not powered | 8500 | 7000 | 4000 | 2500 | ||
| Total | 10000 | 8000 | 5000 | 3000 | ||
| Overload and short circuit characteristics | Three-stage protection,electronically adjustable,see "Description of Protection Characteristics"for details | |||||
| Overvoltage protection value (V) | Set value (250~300)±5% | |||||
| Undervoltage protection value (V) | Set value(145~200)±5% | |||||
| Link control delay time(ms) | ≤40ms | |||||
| Communication delay time(ms) | ≤200ms | |||||
Core Features
Equipped with a high-performance 32-bit ARM microprocessor, it can process signals in real time and implement intelligent control to ensure operational response speed and accuracy.
Equipped with LCD Chinese/English display, the human-computer interaction interface is clear and friendly, the operation process is simple and easy to understand, and the usage threshold is lowered.
For residual current (leakage) protection, it supports online setting of residual current gear and has a reclosing function to improve fault handling efficiency.
It can monitor and track the residual current in the line in real time, automatically adjust the protection gear, ensure the continuous and stable operation of the product, and enhance operational reliability.
It has three-stage protection: long delay, short delay, and instantaneous. It adopts an electronic tripping design that is independent of the power supply voltage. The protection logic is more accurate and is not affected by voltage fluctuations.
The strong breaking capacity can reliably deal with line short-circuit faults, avoid fault expansion, and ensure the security of the power distribution network.
Integrated overvoltage protection, undervoltage protection, and phase loss protection functions fully cover voltage anomaly and phase failure scenarios.
It can display key operating data such as line residual current, three-phase power supply voltage, load current, etc. in real time, allowing users to intuitively grasp the line status.
Protection functions and related parameters can be set and modified online without powering off, improving operation and maintenance flexibility.
It can accurately identify and display trip types (including residual current, lockout, overload, undervoltage, overvoltage, and phase loss), and supports the storage, query, and deletion of trip records to facilitate fault tracing and analysis.
Optional Configuration
Network version: With communication functions, it can realize remote signaling (remote monitoring of equipment status), telemetry (remote collection of operation data), remote control (remote control of equipment start and stop), and remote adjustment (remote adjustment of parameters), adapting to the needs of intelligent power distribution management.
Lightning protection module: supports pluggable installation and can be flexibly selected according to the requirements of the use environment to enhance the equipment's ability to resist lightning strikes.
Infrared communication function: Data interaction can be achieved through infrared, which facilitates device debugging and data reading in specific scenarios.
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box