Leave Your Message

Smart Residual MCCB(Photovoltaic Type) TDK3ELG

The intelligent residual current circuit breaker (photovoltaic type) has a rated insulation voltage of 1000V and is suitable for three-phase, four-wire, solidly grounded (TT) neutral distribution networks operating at 50Hz, rated voltage 400V, and rated current 800A. Its core function is to provide indirect contact protection, effectively preventing fire risks caused by ground fault currents generated by damaged equipment insulation. The circuit breaker can also be used for power distribution, protecting lines and power equipment from damage caused by faults such as overload, undervoltage, short circuit, and single-phase ground fault.

    Model and Meaning

    未标题-1.jpg

    Serial No. Item meaning
    Enterpise code:TALEMOD
    MCCB(Molded Case Circuit Breaker)
    Design No.
    Electronic
    With residual current protection
    G:Photovoltaic type
    Frame grade current(A):Inm=125,Inm=250,Inm=400,Inm=630,Inm=800
    Automatic reclosing
    Y:LCD;B:Bluetooth
    Accessory code
    ZB:Carrier module
    W:Temperature detection

    Main Technical Parameters

    Model TDK3EL-125CY
    TDK3EL-125CS
    TDK3EL-250CY
    TDK3EL-250CS
    TDK3EL-400CY
    TDK3EL-400CS
    TDK3EL-630CY
    TDK3EL-630CS
    TDK3EL-800CY
    TDK3EL-800CS
    Frame grade curent Inm(A) 125 250 400 630 800
    No.of poles 3P+N 3P+N 3P+N 3P+N 3P+N
    Rated operating voltage Ue(V) AC400/50Hz
    Rated insulation voltage Ui(V) 1000
    Rated impulse withstand voltage Uimp(kV) 8
    Flashover distance(mm) ≯50 ≯100
    Ultimate short-circuit breaking capacity Icu(kA) 5070(H) 6585(H)
    Operating short-circuit breaking capacity Ics(kA) 3550(H) 4265(H)
    Rated residual short-circuit making (breaking) capacity I△m(kA) 12.5  17.5(H) 16.25  21.5(H) 16.25
    Rated short-time withstand current Icw(kA)/s 1.5 3 5 8 10
    Residual current operating characteristics AC type
    Rated residual operating curent I△n(mA) 50/100/200/300/400/500/600/800
    MCU automatic tracking or manual setting
    100/200/300/400/500/600/800/
    1000 MCU automatic tracking or manual setting
    Residual operating time characteristics Delayed/non-delayed type
    Limit non-drive time of delayed type(s) 0.06/0.1/0.2 Optional:2I△n
    Breaking time (s) I△n≤0.5;2I△n≤0.2;5I△n≤0.15
    Auto reclosing time (s) 20~60
    Operational performance (times) Powered 1500 1000 1000 500
    Not powered 8500 7000 4000 2500
    Total 10000 8000 5000 3000
    Overload and short circuit characteristics Three-stage protection,electronically adjustable,see "Description of Protection Characteristics"for details
    Overvoltage protection value (V) Set value (250~300)±5%
    Undervoltage protection value (V) Set value(145~200)±5%
    Link control delay time(ms) ≤40ms
    Communication delay time(ms) ≤200ms

    Core Features

    Equipped with a high-performance 32-bit ARM microprocessor, it can process signals in real time and implement intelligent control to ensure operational response speed and accuracy.
    Equipped with LCD Chinese/English display, the human-computer interaction interface is clear and friendly, the operation process is simple and easy to understand, and the usage threshold is lowered.
    For residual current (leakage) protection, it supports online setting of residual current gear and has a reclosing function to improve fault handling efficiency.
    It can monitor and track the residual current in the line in real time, automatically adjust the protection gear, ensure the continuous and stable operation of the product, and enhance operational reliability.
    It has three-stage protection: long delay, short delay, and instantaneous. It adopts an electronic tripping design that is independent of the power supply voltage. The protection logic is more accurate and is not affected by voltage fluctuations.
    The strong breaking capacity can reliably deal with line short-circuit faults, avoid fault expansion, and ensure the security of the power distribution network.
    Integrated overvoltage protection, undervoltage protection, and phase loss protection functions fully cover voltage anomaly and phase failure scenarios.
    It can display key operating data such as line residual current, three-phase power supply voltage, load current, etc. in real time, allowing users to intuitively grasp the line status.
    Protection functions and related parameters can be set and modified online without powering off, improving operation and maintenance flexibility.
    It can accurately identify and display trip types (including residual current, lockout, overload, undervoltage, overvoltage, and phase loss), and supports the storage, query, and deletion of trip records to facilitate fault tracing and analysis.

    Optional Configuration

    Network version: With communication functions, it can realize remote signaling (remote monitoring of equipment status), telemetry (remote collection of operation data), remote control (remote control of equipment start and stop), and remote adjustment (remote adjustment of parameters), adapting to the needs of intelligent power distribution management.
    Lightning protection module: supports pluggable installation and can be flexibly selected according to the requirements of the use environment to enhance the equipment's ability to resist lightning strikes.
    Infrared communication function: Data interaction can be achieved through infrared, which facilitates device debugging and data reading in specific scenarios.

    Creating a New Chapter in Smart Electrical Partnerships

    • Submit your needs for a tailored electrical solution
    • A decade of technical expertise, 24/7 rapid response
    • Every electrical challenge you face sparks our innovation

    Send An Inquiry