Smart Residual MCCB (Metering Type) TDK5EJ

The rated insulation voltage of the molded case circuit breaker is 1000V, and it is suitable for three-phase four-wire distribution networks with AC 50Hz, rated voltage of 400V, and rated current up to 630A. It is used to provide indirect contact protection to prevent fire hazards caused by ground fault current due to equipment insulation damage. Also can be used to distribute electric energy and protect the line from overload and short circuit. It has protection functions for overvoltage, under-voltage, and phase loss of the line.

    Model and Meaning

    未标题-1.jpg

    Serial No. Item meaning
    Enterprise code: TALEMOD
    MCCB (Molded Case Circuit Breaker)
    Design No.
    Electronic & adjustable
    Metering type
    Frame grade current (A): Inm=125,Inm=250,Inm=400,Inm=630
    Breaking capacity: S: Standard; L: Middle breaking; M: High breaking
    Automatic reclosing
    LCD display
    No. of poles: 3: three-pole; 4: four-pole
    None: means no auxiliary; 320: means one group of auxiliary;360: means two groups of auxiliary
    Photovoltaic
    None: indicates no carrier module; ZB: indicates single-mode carrier;TB: indicates dual-mode carrier
    None: indicates no topology identification; TP: indicates topology identification
    3W: Indicates 3-way temperature detection; 6W: Indicates 6-way temperature detection

    Main Technical Parameters

    Model TDK5E-125 TDK5E-250 TDK5E-400 TDK5E-630
    Frame grade rated current Inm(A) 125 250 400 630
    No.of poles 3P/4P
    Rated operating voltage Ue(V) AC400/50Hz
    Rated insulation voltage UiV) 1000
    Rated impulse withstand voltage Uimp(kV) 8
    Flashover distance(mm) ≠50 ×100
    Ultimate short-circuit breaking capacity Icu(kA) 25(S)36(L)50(M) 36(S)35(L)50(M) 35(S)65(L)70(M) 50(S)65(L)70(M)
    Operating short-circuit breaking capacity Ics(kA) 20(S)25(L)35(M) 25(S)35(L)35(M) 35(S)42(L)50(M) 50(S)50(L)70(M)
    Rated short-time withstand current Icw(kA)/s 1.5 3 5 8
    Auto reclosing time (s) ≤2s
    Powered 1500 1000 1000 1000
    Operational performance (times) Not powered 8500 7000 4000 4000
    Total 10000 8000 5000 5000
    Overload and short circuit characteristics Three-stage protection,electronically adjustable
    Overvoltage protection value (V) Set value(231~330)/default value 282V
    Undervoltage protection value (V) Set value(88~209)/default value 187V
    Phase loss protection value(V) Set value(10~130)/default value 30V
    Link control delay time(ms) ≤40ms
    Communication delay time(ms) ≤200ms

    Main Functions and Features

    High-performance 32-bit ARM microprocessor is used to carry out signal processing and intelligent control in real time;

    LCD Chinese/English display provides friendly HMi and simple operation;

    With automatic reclosing function; fast closing speed, closing time <2s;

    Long delay, short delay and instantaneous three-stage protection, electronic tripping mode is appliedwhich is independent of supply voltage;

     High breaking capacity could ensure the reliability of short circuit protection for the line;

    Overvoltage protection, undervoltage protection, phase loss protection and neutral wire missingprotection; Protection functions and parameters can be set and

    modified online;

    Real-time display of three-phase power supply voltage and load current;

    Identification and display of tripping types (remote locking, overload, undervoltage, overvoltage.loss of voltage, phase loss, zero break, etc.), and storage, query and

    deletion;

    Supports four remote functions: remote sianaling, remote measurement, remote control and remote adiustment;

    HPLC pluggable module and micro-power Bluetooth wireless communication;

    0.05In-1.2In measurement can reach level 1.0:

    Real-time measurement of active power, reactive power, apparent power, power factor and other parameters, and accumulation of three phase active power;

    Time control, fee control and other modes are optional, and the application is more flexible;

    Support DL/T645 protocol and Modbus protocol, and automatically identify;

    Real-time monitoring of the incoming terminal terminal block temperature (optional);

    Accuracy level: current and voltage accuracy can reach up to 0.5s level; active and reactive accuracy can reach up to level 1;

    Support active demand over-limit,reactive demand over-limit, current mutation events, current interruption, voltage harmonic contentcurrent harmonic content,

    voltage waveform distortion, current waveform distortion;

    With passive island protection (optional);

    With terminal and contact over-temperature protection (optional);

    With power generation quality monitoring and protection (optional);

    With three-phase unbalanced power generation current monitoring and protection (optional);