-
Modular DIN Rail Products
- Miniature Circuit Breaker (MCB)
- 18mm Width DPN MCB
- Isolator Switch
- Residual Current Circuit Breaker (RCCB)
- Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Fuse
- Arc Fault Detection Device (AFDD)
- Surge Protection Device (SPD)
- Reclosing Device
- MCB Accessories
- Safety Breaker
- Earth Leakage Safety Breaker
- Safety Breaker with Outer Cover
- Earth Leakage Satety Breaker with Outer Cover
- Plug in Type Miniature Circuit Breaker (MCB)
- Plug in Type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Modular Contactor
- Relay
- Transfer Switch
- Smart Molded Case Circuit Breakers
- PV Systems
- Distribution Box
DC lsolator Switch TDDH5
Technical Data
| Standard:lEC60947-3 |
| Ui:1200V DC |
| Ue:600V 800V1000V1200VDC |
| Ie:10A16A20A25A32A |
| Temperature:-40°C~+85°C |
Product Introduction
Talemod DC isolating switch is an important safety and operation electrical device in DC power distribution system. Its core design purpose is to provide an "air break point" after other equipment interrupts the current, thus achieving safe isolation of the circuit.
Core Features
Equipment inspection and maintenance: After opening the disconnector, the clear disconnect gap formed by the contact points provides the highest level of safety for personnel and prevents electric shock accidents.
System operating mode switching: In complex DC power distribution networks, disconnectors are used to energize or de-energize circuits, enabling equipment or lines to be put into or taken out of operation. This enables different operating modes to be implemented or isolate faulty sections.
Emergency power-off point: In an emergency, personnel can manually operate the isolation switch to quickly cut off the power supply, serving as a reliable manual safety barrier.
Product Characteristics
Provide a visible disconnection point: Ensure that in the "off" state, there is a sufficient safe insulation distance between the active contact point and the stationary contact point, and the disconnection state is clearly visible.
Carrying rated current: In the "on" state, the contacts of the disconnector must reliably and continuously carry the maximum continuous operating current of the system without overheating.
Withstand short-term current surges: Disconnectors must possess a certain level of dynamic and thermal stability to withstand short-circuit current surges for a short period of time until the upstream protection device operates to clear the fault. This ensures that the disconnector itself is not damaged in the event of a fault.
Strict "no-load" or "low arc" operation: Switching operation under load is strictly prohibited.
Application Areas
(Applicable to situations where medium and high voltage DC circuits require safety inspection, debugging or electrical isolation)
Photovoltaic power generation system
Electrochemical energy storage system
Electric vehicles and charging infrastructure
Rail transit and electric ships
Industrial and telecommunications power systems
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box

