Air Circuit Breaker TDW1

TDW1 series air circuit breaker is suitable for distribution network with frequency of AC 50Hz, rated current of 630A-6300A, rated insulation voltage of 1000V with rated operational voltages of 400V and 690v, which is used to distribute electric energy and protect lines and power supply equipment from the faults such as overload, undervoltage, short circuit, and single-phase earth faults. It can also be used as an isolating switch. Circuit breaker has a variety of protection functions, which provides precise selective protection, reduces unnecessary outages, and enhances power supply reliability and safety. Circuit breakers rated at 1000A and below can be used for infrequent motor starting, with built-in protection functions. 

    Model and Meaning

    未标题-7.jpg

    Serial No. Item meaning
    Enterprise code:TALEMOD
    Product code
    Design No.
    Frame grade curent(A)
    Low section:Not marked High section:H
    Rated current
    No.of poles
    Type of inteligent controller
    Operating voltage of control loop
    Installation structure

    Taking TDW1-2000/2000A/3P/M/C as an example

    TDW1- 6300(H) / 6300A / 3P 4P / Intelligent controller
    Not marked for fixed circuit breaker 5000A
    Withdrawable:C 4000A
    4000(H) / 4000A
    Not marked for fixed circuit breaker 3600A
    Withdrawable:C 3200A
    3200(H) / 3200A
    Not marked for fixed circuit breaker 2900A
    Withdrawable:C 2500A
    2000A
    2000(H) / 2000A 3H
    3M
    2H
    2M M
    L
    1600A
    1250A
    Not marked forfixed circuit breaker 1000A
    Withdrawable:C 800A
    630A
    400A

    Main Technical Parameters

    Model TDW1-2000(H) TDW1-3200(H)
    Frame grade rated curent Inm(A) 2000(H) 3200(H)
    Rated curent In(A) 630、800 1000、1250、1600 , 2000 2000、2500 2900、3200
    Rated operating voltage Ue(V) AC400,AC690 AC400,AC690
    Rated frequency (Hz) 50 50
    Rated insulation voltage Ui(V) 1000 1000
    Rated impulse withstand voltage Uimp(kV) 12 12
    No.of poles 3,4 3,4
    Total breaking time (ms) ≤30 ≤30
    Closing time (ms) ≤60 ≤70
    Rated ultimate short-circuit breaking capacity Icu(kA) (valid value) AC400V 6580(H) 65120(H)
    AC690V 50 100
    Rated operating short-circuit breaking capacity Ics(kA) (valid value) AC400V 50 65(H) 65 120(H)
    AC690V 50 100
    Rated short-circuit making capacity Icm(kAME value) AC400V 176 220
    AC690V 105 143
    Rated short-time withstand current lcw(1s)(kA)
    (valid value)
    AC400V 50 65(H) 80 120(H)
    AC690V 50 100
    Operational performance (times) Electrical  service life AC400V 10000 10000 8000
    AC690V 5000 5000 5000
    Mechanical  service life Maintenance free 10000 10000 8000
    Maintainable 20000 20000 15000
    Installation type Fixed type
    Drawer type
    Wiring mode of main circuit Fixed type Horizontal wiring,vertical wiring Horizontal and vertical wiring Horizontal wiring
    Drawer type Horizontal wiring,vertical wiring Horizontal and vertical wiring Horizontal wiring
    Overall dimension: W×H×D(mm) Fixed type 3P 370×402×325 422×402×325
    Fixed type 4P 465×402×325 537×402×325
    Drawer type 3P 375×432×421 435×432×421
    Drawer type 4P 470×432×421 550×432×421
    Weight (kg)
    ():Extended busbar type
    Fixed type 3P 39(41.5) 39(41.5) 39(41.5) 46(55) 56(66)
    Fixed type 4P 48(51) 48(51) 48(51) 58(70) 68(82)
    Drawer type 3P 68(69.5) 68(69.5) 68(69.5) 92(98) 96(104)
    Drawer type 4P 79(81) 79(81) 79(81) 108(115) 118(130)

    Model TDW1-4000(H) TDW1-6300(H)
    Frame grade rated curent Inm(A) 4000(H) 6300(H)
    Rated current In(A) 3.20036E+11 4000 5000 6300
    Rated operating voltage Ue(V) AC400,AC690 AC400,AC690
    Rated frequency (Hz) 50 50
    Rated insulation voltage Ui(V) 1000 1000
    Rated impact withstand voltage (kV) 12 12
    Number of poles (P) 3 3,4
    Total breaking time (ms) ≤30 ≤30
    Closing time (ms) ≤70 ≤80
    Rated ultimate short-circuit breaking capacity Icu(kA) (valid value) AC400V 80120(H) 100 120(H)
    AC690V 100 100
    Rated operating short-circuit breaking capacity Ics(kA) (valid value) AC400V 65120(H) 80 120(H)
    AC690V 100 100
    Rated short-circuit making capacity Icm(kAME value) AC400V 220 264
    AC690V 143 176
    Rated short-time withstand current Icw(1s)(kA)
    (valid value)
    AC400V 65120(H) 80 120(H)
    AC690V 100 100
    Operational Electrical  service life AC400V 8000 1000
    AC690V 5000 600
    Mechanical  service life Maintenance free 8000 3000
    Maintainable 15000 5000
    Installation type Fixed type
    Drawer type
    Wiring mode of main circuit Fixed type
    Drawer type Horizontal wiring Horizontal wiring
    Overall dimension: W×H×D(mm) Fixed type 3P
    Fixed type 4P
    Drawer type 3P 550×432×494 895×432×494
    Drawer type 4P 895×432×494
    Weight  (kg)
    ():Extended busbar type
    Fixed type 3P
    Fixed type 4P
    Drawer type 3P 132 201 215 215
    Drawer type 4P 213 230 230

    Normal Working and Installation Conditionsr

    ◆The upper limit of ambient temperature should not exceed+40℃,while the lower limit of ambient temperature should not belower than-5℃; and the 24h average temperature should not exceed+35℃;
    Note:
    1)If the ambient temperature exceeds+40℃,the volume should be reduced.See the relevant volume reduction coefficient part of this manual;
    2)Products with the upper limit of ambient air temperature not exceeding+60℃ and the lower limit not lower than-25℃ can be specially ordered;
    ◆Altitude:The altitude of the installation site does not exceed 2000m,and reference can be made to the high altitude volume reduction coefficient;
    ◆Atmospheric conditions:When the ambient air temperature is +40℃,the relative humidity of the air does not exceed 50%,and higher humidity can be allowed at lower temperature,for example,t can reach 90%at+20℃.Special measures should be adopted for condensation occasionally caused by temperature variation;
    ◆Pollution   level:3;
    ◆Installtion category:The  installation category of main circuit  (including  undervoltage trip coil  is of class V;Control circuit and auxiliary circuit are of class Ⅲ;
    ◆Insallaion conditions:The circuit-breaker shall be installed according to the requirements of the manual,and the vertical inclination of thee circuit-breaker shall not exceed 5°;
    ◆Requirements of installation protection leve:IP30 and IP40(which are installed in the cabinet room with door frame and plexiglass cover);
    ◆Usage category.A or B.

    Product Featuresr

    ◆The contact system is installed in the insulation chamber,and the contact system of each phase shall be the multi-channel sheet structure; The electrodynamic compensation is realized to ensure the high breaking ability of the circuit-breaker;
    ◆Advanced arc extinguishing system and protective cover ensure "zero flashing"and make products more safe;
    ◆ The circuit-breaker is closed by the energy storage mechanism,and the closing speed is fast;
    ◆The operating mechanism is installed in the front centre of the circuit breaker and completely separated from the main circuit,which can make each phase pole have stable and consistent contact final pressure and play an important role in ensuning the realization of temperature rise and breaking index,especially the circuit-breaker with 6300A shell frame is more important;
    ◆The centre operation mechanism is convenient for the centre symmetrical opening of the complete cabinet door,which improves the appearance quality of the complete cabinet;
    ◆With 3-pole and 4-pole;
    ◆ Withdrawable and fixed types;
    ◆Wire can be installed from the bottom,with horizontal and vertical wiring modes;
    ◆Intelligent controller has multiple protection functions,which can realize selective protection;For 2M,3M LCD display controlle,in addition to the current display and protection,the measurement and protection of the function such as voltage,frequency,phase sequence and power can be increasedwhich makes the functions more powerful;
    2H and 3H inteligent controllers have the functions of communication networking and monitoring.Modbus,Profibus and Device-net protocols can be applied to facilitate bus integrated management Remote control,telemetry,remote communication and remote regulation could be realized;
    ◆Various forms of mechanical interlocking (types of lever and steel cable),withdrawable lock,door interlocking and safety-guaranteed open position lock,reaizing the locking of circuit breaker,and the whole series is universal.