Leave Your Message

6KA residual current circuit breaker with overcurrent protection TDR9

Talemod TDR9 residual current circuit breaker with overcurrent protection simultaneously provides both overcurrent/short-circuit protection and earth leakage protection. The product is applied to the lines with AC 50/60Hz, rated voltage of 240V/415V, and rated working current up to 63A. The rated short-circuit breaking capacity has 6KA. The RCBO adopts modular design and complies with the standard IEC61009-1, has reliable performance, accurate protection characteristics, small size, and is suitable for industrial and commercial lighting distribution lines.

    Technical Data

    Standard IEC61009-1
    Mode Electronic/Electromagnetic
    Type A、AC
    Tripping curve BCD
    Pole 1P+N,3P+N
    Rated voltage 230/400V~
    Rated frequency 50/60Hz
    Rated current 6-63A
    Rated residual operating current(l△n) 30、100、300mA
    Residual operating current range 0.5l△n~l△n
    Ratedconditionalshort-circuit current(lnc) 6KA/10KA
    Energy limiting class 3
    Electrical and Mechanical life 20000

    Overload Current Protection Characteristics

    Test Procedure Type Test Current Initial State Tripping or Non-tripping
    Time Limit
    Expected Result Remark
    A B、C 1.13In cold t≤1h no tripping
    B B、C 1.45In after test A t<1h tripping The curent steadily rise to the
    specifed walue within5s
    C B、C 2.55In cold 1s<t<60s(In≤32A)
    1s<t<120s(In>32A)
    tripping
    D B 3In cold t≤0.1s no tripping Turn on theauxiliary switch toclose the current
    C 5In
    D 10In
    E B 5In cold t<0.1s tripping Turn on theauxiliary switch toclose the current
    C 10In
    D 20In

    Residual Current Operating Breaking Time

    type In/A I△n/A Residual Current(I△)Is Corresponding To The Following Breaking Time(S)
    ACtype Any value Anyvalue In 2In 5In 5A,10A,20A,50A
    A type >0.01 1.4In 2.8In 7In
    0.3 0.15     0.04 0.4             max breaking time
    The general type RCBO whose current I△n is 0.03mA less can use 0.25A instead of 5I△n.

    Installation

    Protection degree IP20
    Ambient temperature -25~+40℃
    Storage temperature -25~+70℃
    Terminal connection type Cable/U-type busbar/Pin -type busbar
    Terminal size top/bottom for cable 25mm²
    Tightening torque 2.5N.m
    Connection Top and bottom

    Overall and mounting dimensioned chart

    TDR9-2.jpg

    Product overview

    Are you concerned about hidden leakage currents in aging wiring? Are you frustrated by frequent nuisance tripping caused by circuit overloads? Our RCBO is the definitive solution to these common and worrying electrical problems. It proactively detects even minor leakage currents resulting from insulation degradation—issues that are invisible to the naked eye—allowing for intervention before a hazardous situation develops. Its precise overload protection is calibrated to prevent fire risks from overheated cables while offering high immunity to the temporary inrush currents generated by appliances like motors and transformers, thus avoiding unnecessary power interruptions. By upgrading your electrical system with our RCBO, you are implementing a comprehensive and robust solution that effectively and permanently resolves core safety concerns, bringing your property's electrical safety into the 21st century.

    Creating a New Chapter in Smart Electrical Partnerships

    • Submit your needs for a tailored electrical solution
    • A decade of technical expertise, 24/7 rapid response
    • Every electrical challenge you face sparks our innovation

    Send An Inquiry