6KA residual current circuit breaker with overcurrent protection TDR4
Technical Data
| Standard | IEC61009-1 |
| Mode | Electronic |
| Type | A、AC |
| Tripping curve: | BCD |
| Pole | 1P+N |
| Rated voltage | 240V~ |
| Rated frequency | 50/60Hz |
| Rated current | 6-40A |
| Rated residual operating current(l△n) | 30、100、300mA |
| Residual operating current range | 0.5l△n~l△n |
| Ratedconditionalshort-circuit current(lnc) | 6KA/10KA |
| Energy limiting class | 3 |
| Electrical and Mechanical life | 20000 |
Overload Current Protection Characteristics
| Test Procedure | Type | Test Current | Initial State | Tripping or Non-tripping Time Limit |
Expected Result | Remark |
| A | B、C | 1.13In | cold | t≤1h | no tripping | |
| B | B、C | 1.45In | after test A | t<1h | tripping | The curent steadily rise to the specifed walue within5s |
| C | B、C | 2.55In | cold | 1s<t<60s(In≤32A) 1s<t<120s(In>32A) |
tripping | |
| D | B | 3In | cold | t≤0.1s | no tripping | Turn on theauxiliary switch toclose the current |
| C | 5In | |||||
| D | 10In | |||||
| E | B | 5In | cold | t<0.1s | tripping | Turn on theauxiliary switch toclose the current |
| C | 10In | |||||
| D | 20In |
Residual Current Operating Breaking Time
| type | In/A | I△n/A | Residual Current(I△)Is Corresponding To The Following Breaking Time(S) | |||
| ACtype | Any value | Anyvalue | In | 2In | 5In | 5A,10A,20A,50A |
| A type | >0.01 | 1.4In | 2.8In | 7In | ||
| 0.3 | 0.15 | 0.04 | 0.4 max breaking time | |||
| The general type RCBO whose current I△n is 0.03mA less can use 0.25A instead of 5I△n. | ||||||
Installation
| Protection degree | IP20 |
| Ambient temperature | -25~+40℃ |
| Storage temperature | -25~+70℃ |
| Terminal connection type | Cable |
| Terminal size top/bottom for cable | 25mm² |
| Tightening torque | 3.0N.m |
| Connection | Top and bottom |
Overall and mounting dimensioned chart

Product Overview
From a user's perspective, this RCBO delivers comprehensive value through simplicity, peace of mind, and cost-effectiveness. The all-in-one design streamlines procurement, inventory management, and system design, eliminating the complexity of sourcing and coordinating separate components. Installation is faster and more straightforward, saving valuable time for both end-users and electricians. Most importantly, it provides an unparalleled level of safety assurance, allowing you to rest easy knowing that your family, employees, and property are protected against electrical threats. By proactively preventing electrical fires and equipment damage, it effectively averts potential catastrophic losses. The return on investment is realized the very moment a hazardous incident is prevented, making it not just a regulatory requirement but a smart, economical choice for long-term risk management and peace of mind.
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box