6KA reclosing device TDRDL-C
Technical Data
| Control mode | Controlled by switch |
| Supply terminals | A1-A2 |
| Voltage range | DC12V,DC24V~48V |
| Power input | DC max.1W(standby)max.20W(action) |
| Voltage range | AC 220V(50-60Hz) |
| Supply voltage tolerance | -10%;+10% |
| Power input | AC max.1VA(standby)max.20VA(action) |
| Supply voltage tolerance | -10%;+10% |
| Supplyindication | red LED |
| Action time | ≤1s |
| Auto reclosing times | |
| Auto reclosing interval time | |
| Reset the closing times | |
| Mechanical life | 10000 |
| Electrical life(AC1) | 4000 |
| Operating temperature | -20℃to +55℃(-4℉ to 131℉) |
| Storage temperature | -35℃℃ to +75℃(-22° to 158℉) |
| Mounting/DlN rail | Din rail EN/IEC 60715 |
| Protection degree | IP20 |
| Operating position | Any |
| Overvoltage cathegory | III |
| Pollution degree | 2 |
| Max.cable size(mm) | Solid wire max.1x2.5 or 2x1.5/with sleeve max.1 x2.5(AWG 12) |
| Dimensions | 82x18x78mm |
| Weight | 80g |
Overall and mounting dimensioned chart

Product Overview
Talemod reclosing device is a fundamental protection equipment for distribution networks, specifically designed to automatically restore power supply after the elimination of transient line faults. Based on time-sequence logic control principle, the device automatically performs 1-3 reclosing operations according to preset time delays after circuit breaker tripping due to faults. Its core value lies in effectively addressing transient faults caused by lightning strikes, bird contact, etc., reducing outage time caused by non-permanent faults, and improving power supply continuity.
Core Functions
Standard Reclosing Sequence: Supports "open-close-open-close-open" standard operation cycle with adjustable reclosing times.
Precise Time Delay Control: Provides adjustable delay settings from 0.5-300 seconds to meet different differential coordination requirements.
Lockout Logic Protection: Automatically locks out when reclosing onto permanent faults, preventing multiple impact damage to equipment.
Local Manual Operation: Equipped with local operation knob, supporting operation/withdrawal/test mode switching.
Main Application Fields
Rural Distribution Systems: 10kV overhead line section circuit breakers.
Industrial Power Supply Lines: Protection for mining area power supply mains.
Suburban Distribution Networks: Fault handling for long-distance radial lines.
Simple Branch Lines: Distribution transformer high-voltage side control.
Temporary Power Systems: Construction power supply protection.
Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box