10KA Miniature Circuit Breaker TDM5-125
Technical Data
| Standard | IEC60947-2 |
| Rated current (In) | 63-125A |
|
Poles |
1P 2P 3P 4P |
| Rated voltage (Ue) | 240-125A |
| lnsulation voltage (Ui) | 500V |
| Rated frequency | 50/60Hz |
| Rated breaking capacity (lcn) | 10KA |
| Rated operating short circuit breaking capacity (lcs) | 7.5KA |
| Energy limiting class | 3 |
| Tripping curve | B C D |
| Electrical and Mechanical life | 20000 |
Installation
| Protection degree | IP20 |
| Reference temperature for setting of thermal element | 30℃ |
| Ambient temperature | -25~+40℃ |
| Storage temperature | -25~+70℃ |
| Terminalconnection type | Cable/Pin -type busbar |
| Terminal size top/bottom for cable | 50m㎡ |
| Tightening torque | 2.5N.m |
| Connection | Top and bottom |
Combination with accessories
| SHUNT RELEASE | Yes |
| AUXILIARY CONTACT | Yes |
| ALARM CONTACT | Yes |
| UNDER VOLTAGE RELEASE | Yes |
| OVER VOLTAGE RELEASE | Yes |
Product Overview
A 125A miniature circuit breaker (MCB) is a critical protection device used in electrical distribution systems, specifically designed for high-current circuits. It integrates dual functions of overload protection and short-circuit protection. When the current in the circuit exceeds the rated value (e.g., due to overload) or experiences a severe short-circuit fault, it can quickly and reliably automatically cut off the power supply, effectively preventing conductor overheating, equipment damage, and electrical fire hazards.
Core Functions
Precise Overload Protection:Utilizing a thermal tripping mechanism with a bi-metallic strip, the MCB responds to persistent overcurrents that exceed its rated value (e.g., 125A). This protection is time-delayed, allowing for harmless, temporary current surges (like motor start-ups) without nuisance tripping, while disconnecting the circuit in the event of a sustained overload that could cause insulation damage and conductor overheating.
Rapid Short-Circuit Protection:Equipped with an electromagnetic tripping mechanism, the MCB instantaneously detects and reacts to very high fault currents typical of short circuits. This rapid trip action (within milliseconds) minimizes the destructive energy let-through, thereby protecting downstream cables, connected equipment, and the overall installation from severe thermal and mechanical stress.
Reliable Switching and Isolation:The device serves as a manual ON/OFF switch for routine control of the circuit. Furthermore, in the tripped or manually switched OFF position, it provides a visible and reliable isolation gap, ensuring the circuit is de-energized for safe maintenance and inspection.
Enhanced Electrical Fire Prevention:By reliably interrupting both overload and short-circuit faults—two primary causes of excessive heat buildup—the MCB acts as a crucial first line of defense against the risk of electrical fires originating from the wiring installation.