Technical Data
| Standard | IEC60898-1 |
| Rated current(In) | 1-63A |
| Poles | 1P 2P 3P 4P |
| Rated voltage(Ue) | 1P:240/415V~ 2/3/4P:415~ |
| Insulation voltage(Ui) | 500V |
| Rated frequency | 50/60Hz |
| Rated breaking capacity (Icn) | 10KA |
| Rated operating short circuit breaking capacity(lcs) | 7.5KA |
| Energy limiting class | 3 |
| Tripping curve | B C D |
| Electrical and Mechanical life | 20000 |
Overload Current Protection Characteristics
| Test Procedure | Type | Test Current | Initial State | Trping or Non-tripping Time Limit |
Expected Result | Remark |
| A | B、C、D | 1.13In | cold | t≤1h | no tripping | |
| B | B、C、D | 1.45In | after test A | t<1h | tripping | The curent steadily is to the specifed walue within5s |
| C | B、C、D | 2.55In | cold | 1s<t<60s(In≤32A) 1s<t<120s(In>32A) |
tripping | |
| D | B | 3In | cold | t≤0.1s | no tripping | Turn on the |
| C | 5In | auxiliary switch to | ||||
| D | 10In | close the current | ||||
| E | B | 5In | cold | t<0.1s | tripping | Turn on the |
| C | 10In | auxiliary switch to | ||||
| D | 20In | close the current |

Installationn
| Protection degree | IP20 |
| Reference temperature for setting of thermal element | 30℃ |
| Ambient temperature | -25~+40℃ |
| Storage temperature | -25~+70℃ |
| Terminal connection type | Cable/U-type busbar/Pin -type busbar |
| Terminal size top/bottom for cable | 25mm² |
| Tightening torque | 2.5N.m |
| Connection | Top and bottom |
Combination with accessories
| Shunt release | YES |
| Auxiliary contact | YES |
| Alarm contact | YES |
| Under voltage release | YES |
| Over voltage release | YES |
Product Features & Advantages
Safe and Reliable: Provides precise overload and short-circuit protection, significantly reducing the risk of electrical fires.
Manual Control: Offers reliable manual "ON" and "OFF" operation, functioning as an isolating switch for convenient equipment maintenance and repair.
Easy Operation: After fault clearance, power supply can be restored simply by flipping the handle back to the "ON" position.
Modular Design: Features standardized dimensions (modular) for easy installation on distribution board mounting rails, saving space and simplifying installation and maintenance.
Overall and mounting dimensioned chart

Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems
Distribution Box