Modular DIN Rail Products
- Miniature Circuit Breaker (MCB)
- 18mm Width DPN MCB
- Isolator Switch
- Residual Current Circuit Breaker (RCCB)
- Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Fuse
- Arc Fault Detection Device (AFDD)
- Surge Protection Device (SPD)
- Reclosing Device
- MCB Accessories
- Safety Breaker
- Earth Leakage Safety Breaker
- Safety Breaker with Outer Cover
- Earth Leakage Satety Breaker with Outer Cover
- Plug in Type Miniature Circuit Breaker (MCB)
- Plug in Type Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
- Modular Contactor
- Relay
- Transfer Switch
- Smart Molded Case Circuit Breakers
- PV Systems
- Distribution Box
10KA Miniature Circuit Breaker TDM3
Technical Data
| Standard | IEC60898-1 |
| Rated current (In) | 1-63A |
| Poles | 1P2P 3P4P |
| Rated voltage(Ue) | 1P:240/415V~ 2/3/4P:415~ |
| Insulation voltage(Ui) | 500V |
| Rated frequency | 50/60Hz |
| Rated breaking capacity (Icn) | 10KA |
| Rated operating short circuit breaking capacity(Ics) | 7.5KA |
| Energy limiting class | 3 |
| Tripping curve | B C D |
| Electrical and Mechanical life | 20000 |
Overload Current Protection Characteristics
| Test Procedure | Type | Test Current | Initial State | Trping or Non-tripping Time Limit |
Expected Result | Remark |
| A | B、C、D | 1.13In | cold | t≤1h | no tripping | |
| B | B、C、D | 1.45In | after test A | t<1h | tripping | The curent steadily is to the specifed walue within5s |
| C | B、C、D | 2.55In | cold | 1s<t<60s(In≤32A) 1s<t<120s(In>32A) |
tripping | |
| D | B | 3In | cold | t≤0.1s | no tripping | Turn on the |
| C | 5In | auxiliary switch to | ||||
| D | 10In | close the current | ||||
| E | B | 5In | cold | t<0.1s | tripping | Turn on the |
| C | 10In | auxiliary switch to | ||||
| D | 20In | close the current |

Installationn
| Protection degree | IP20 |
| Reference temperature for setting of thermal element | 30℃ |
| Ambient temperature | -25~+40℃ |
| Storage temperature | -25~+70℃ |
| Terminal connection type | Cable/U-type busbar/Pin -type busbar |
| Terminal size top/bottom for cable | 25mm² |
| Tightening torque | 3.0N.m |
| Connection | Top and bottom |
Combination with accessories
| Auxillary contact | YES |
| Alarm contact | YES |
| Shunt release | YES |
| Under voltage release | YES |
Product Features & Advantages
Safe and reliable, preventing accidents before they happen: With precise overload and short-circuit dual protection functions, it can monitor circuit anomalies in real time and respond quickly, significantly reducing the risk of electrical fires at the source and building a solid defense line for power safety.
Manual control, flexible operation and maintenance: Supports stable and reliable manual on/off operation and can be used directly as an isolating switch. When equipment needs to be repaired or maintained, it can quickly disconnect the circuit, providing a safe operating environment for operators and improving operational convenience.
Easy operation and quick reset: After the circuit fault is eliminated, there is no need for complicated operations. Just turn the operating handle back to the "on" position to easily restore power supply, reducing power outage downtime and ensuring power continuity.
Modular design and efficient installation: The modular structure with standardized dimensions can be directly adapted to the distribution board mounting rails, which not only effectively utilizes the installation space but also simplifies the installation process and subsequent maintenance steps, reducing overall construction and operation and maintenance costs.
Overall and mounting dimensioned chart

Creating a New Chapter in Smart Electrical Partnerships
• Submit your needs for a tailored electrical solution
• A decade of technical expertise, 24/7 rapid response
• Every electrical challenge you face sparks our innovation

Modular DIN Rail Products
Smart Molded Case Circuit Breakers
PV Systems