Leave Your Message

10-30A Earth Leakage Safety Breaker TD50LE

Talemod TD50LE earth leakage safety breakers are designed to provide an absolutely reliable physical power-off point for industrial equipment, electrical cabinets, and machinery, ensuring the safety of operators and maintenance personnel. The product is applied to the lines with AC 50/60Hz, rated voltage of 220V, and rated working current up to 40A. The rated short-circuit breaking capacity has 1.5/2.5KA, and complies with the standard IEC60947-2, has reliable performance, accurate protection characteristics, small size, and is suitable for industrial and commercial lighting distribution lines.

    Technical Data

    Standard IEC60947-2
    Rated current (ln) 10-40A
    Poles & element 2P1E
    Model Electromagnetic
    Type AC
    Tripping curve B/C/D
    Rated voltage (Ue) 220V
    Rated residual operatingcurrent(l△n) 15mA/30mA 
    Rated conditional short-circuit current (inc) 1.5KA,2.5KA

    Product Overview

    An Earth Leakage Safety Breaker is a fundamental life-saving device in the field of electrical safety. Its primary purpose is to prevent fatal electric shocks by continuously monitoring the difference between the current flowing into and out of an electrical circuit. This imbalance signals an "earth leakage," which occurs when current finds an unintended path to earth, such as through a person who has touched a live part or through damaged cable insulation. When this leakage current reaches a pre-set, dangerous threshold, the breaker acts with remarkable speed, disconnecting the power within milliseconds. This rapid response is faster than the time it takes for an electric current to cause lethal ventricular fibrillation in the human heart, making it an indispensable guardian against electrocution.

    Core Functions

    Earth Leakage Safety Breakers incorporate a range of features designed to enhance both safety and usability. High sensitivity is paramount, allowing them to react to minute leakage currents that are hazardous to human life. Their rapid disconnection characteristic ensures that the duration of any fault current is minimized, drastically reducing the risk of injury. A clear mechanical indicator provides immediate visual confirmation of the contact position. A dedicated monthly test button is a critical feature, enabling users to easily verify the proper functionality of the entire tripping mechanism by simulating a fault condition. Furthermore, advanced models may offer additional integrated protections, such as overvoltage protection, which safeguards connected appliances and wiring from damage caused by power grid surges, thereby delivering a more comprehensive safety solution.

    Main Application Fields

    The application of Earth Leakage Safety Breakers is mandated in all locations with an elevated risk of electric shock. In residential settings, electrical codes require their installation in damp or wet areas such as kitchens, bathrooms, laundry rooms, garages, and for all outdoor sockets. Commercially and industrially, they are compulsory safety components in distribution systems for construction sites, manufacturing workshops, laboratories, data centers, and commercial kitchens. In these diverse environments, the breaker acts as the ultimate safeguard, protecting individuals from electric shock in scenarios involving faulty appliance insulation, damaged cables, or accidental contact with live parts. Its role is particularly critical where electricity and water are in close proximity, making it a non-negotiable element of modern electrical safety protocols.